fortios.system.Managementtunnel
Explore with Pulumi AI
Management tunnel configuration.
Example Usage
import * as pulumi from "@pulumi/pulumi";
import * as fortios from "@pulumiverse/fortios";
const trname = new fortios.system.Managementtunnel("trname", {
allowCollectStatistics: "enable",
allowConfigRestore: "enable",
allowPushConfiguration: "enable",
allowPushFirmware: "enable",
authorizedManagerOnly: "enable",
status: "enable",
});
import pulumi
import pulumiverse_fortios as fortios
trname = fortios.system.Managementtunnel("trname",
allow_collect_statistics="enable",
allow_config_restore="enable",
allow_push_configuration="enable",
allow_push_firmware="enable",
authorized_manager_only="enable",
status="enable")
package main
import (
"github.com/pulumi/pulumi/sdk/v3/go/pulumi"
"github.com/pulumiverse/pulumi-fortios/sdk/go/fortios/system"
)
func main() {
pulumi.Run(func(ctx *pulumi.Context) error {
_, err := system.NewManagementtunnel(ctx, "trname", &system.ManagementtunnelArgs{
AllowCollectStatistics: pulumi.String("enable"),
AllowConfigRestore: pulumi.String("enable"),
AllowPushConfiguration: pulumi.String("enable"),
AllowPushFirmware: pulumi.String("enable"),
AuthorizedManagerOnly: pulumi.String("enable"),
Status: pulumi.String("enable"),
})
if err != nil {
return err
}
return nil
})
}
using System.Collections.Generic;
using System.Linq;
using Pulumi;
using Fortios = Pulumiverse.Fortios;
return await Deployment.RunAsync(() =>
{
var trname = new Fortios.System.Managementtunnel("trname", new()
{
AllowCollectStatistics = "enable",
AllowConfigRestore = "enable",
AllowPushConfiguration = "enable",
AllowPushFirmware = "enable",
AuthorizedManagerOnly = "enable",
Status = "enable",
});
});
package generated_program;
import com.pulumi.Context;
import com.pulumi.Pulumi;
import com.pulumi.core.Output;
import com.pulumi.fortios.system.Managementtunnel;
import com.pulumi.fortios.system.ManagementtunnelArgs;
import java.util.List;
import java.util.ArrayList;
import java.util.Map;
import java.io.File;
import java.nio.file.Files;
import java.nio.file.Paths;
public class App {
public static void main(String[] args) {
Pulumi.run(App::stack);
}
public static void stack(Context ctx) {
var trname = new Managementtunnel("trname", ManagementtunnelArgs.builder()
.allowCollectStatistics("enable")
.allowConfigRestore("enable")
.allowPushConfiguration("enable")
.allowPushFirmware("enable")
.authorizedManagerOnly("enable")
.status("enable")
.build());
}
}
resources:
trname:
type: fortios:system:Managementtunnel
properties:
allowCollectStatistics: enable
allowConfigRestore: enable
allowPushConfiguration: enable
allowPushFirmware: enable
authorizedManagerOnly: enable
status: enable
Create Managementtunnel Resource
Resources are created with functions called constructors. To learn more about declaring and configuring resources, see Resources.
Constructor syntax
new Managementtunnel(name: string, args?: ManagementtunnelArgs, opts?: CustomResourceOptions);
@overload
def Managementtunnel(resource_name: str,
args: Optional[ManagementtunnelArgs] = None,
opts: Optional[ResourceOptions] = None)
@overload
def Managementtunnel(resource_name: str,
opts: Optional[ResourceOptions] = None,
allow_collect_statistics: Optional[str] = None,
allow_config_restore: Optional[str] = None,
allow_push_configuration: Optional[str] = None,
allow_push_firmware: Optional[str] = None,
authorized_manager_only: Optional[str] = None,
serial_number: Optional[str] = None,
status: Optional[str] = None,
vdomparam: Optional[str] = None)
func NewManagementtunnel(ctx *Context, name string, args *ManagementtunnelArgs, opts ...ResourceOption) (*Managementtunnel, error)
public Managementtunnel(string name, ManagementtunnelArgs? args = null, CustomResourceOptions? opts = null)
public Managementtunnel(String name, ManagementtunnelArgs args)
public Managementtunnel(String name, ManagementtunnelArgs args, CustomResourceOptions options)
type: fortios:system:Managementtunnel
properties: # The arguments to resource properties.
options: # Bag of options to control resource's behavior.
Parameters
- name string
- The unique name of the resource.
- args ManagementtunnelArgs
- The arguments to resource properties.
- opts CustomResourceOptions
- Bag of options to control resource's behavior.
- resource_name str
- The unique name of the resource.
- args ManagementtunnelArgs
- The arguments to resource properties.
- opts ResourceOptions
- Bag of options to control resource's behavior.
- ctx Context
- Context object for the current deployment.
- name string
- The unique name of the resource.
- args ManagementtunnelArgs
- The arguments to resource properties.
- opts ResourceOption
- Bag of options to control resource's behavior.
- name string
- The unique name of the resource.
- args ManagementtunnelArgs
- The arguments to resource properties.
- opts CustomResourceOptions
- Bag of options to control resource's behavior.
- name String
- The unique name of the resource.
- args ManagementtunnelArgs
- The arguments to resource properties.
- options CustomResourceOptions
- Bag of options to control resource's behavior.
Constructor example
The following reference example uses placeholder values for all input properties.
var managementtunnelResource = new Fortios.System.Managementtunnel("managementtunnelResource", new()
{
AllowCollectStatistics = "string",
AllowConfigRestore = "string",
AllowPushConfiguration = "string",
AllowPushFirmware = "string",
AuthorizedManagerOnly = "string",
SerialNumber = "string",
Status = "string",
Vdomparam = "string",
});
example, err := system.NewManagementtunnel(ctx, "managementtunnelResource", &system.ManagementtunnelArgs{
AllowCollectStatistics: pulumi.String("string"),
AllowConfigRestore: pulumi.String("string"),
AllowPushConfiguration: pulumi.String("string"),
AllowPushFirmware: pulumi.String("string"),
AuthorizedManagerOnly: pulumi.String("string"),
SerialNumber: pulumi.String("string"),
Status: pulumi.String("string"),
Vdomparam: pulumi.String("string"),
})
var managementtunnelResource = new Managementtunnel("managementtunnelResource", ManagementtunnelArgs.builder()
.allowCollectStatistics("string")
.allowConfigRestore("string")
.allowPushConfiguration("string")
.allowPushFirmware("string")
.authorizedManagerOnly("string")
.serialNumber("string")
.status("string")
.vdomparam("string")
.build());
managementtunnel_resource = fortios.system.Managementtunnel("managementtunnelResource",
allow_collect_statistics="string",
allow_config_restore="string",
allow_push_configuration="string",
allow_push_firmware="string",
authorized_manager_only="string",
serial_number="string",
status="string",
vdomparam="string")
const managementtunnelResource = new fortios.system.Managementtunnel("managementtunnelResource", {
allowCollectStatistics: "string",
allowConfigRestore: "string",
allowPushConfiguration: "string",
allowPushFirmware: "string",
authorizedManagerOnly: "string",
serialNumber: "string",
status: "string",
vdomparam: "string",
});
type: fortios:system:Managementtunnel
properties:
allowCollectStatistics: string
allowConfigRestore: string
allowPushConfiguration: string
allowPushFirmware: string
authorizedManagerOnly: string
serialNumber: string
status: string
vdomparam: string
Managementtunnel Resource Properties
To learn more about resource properties and how to use them, see Inputs and Outputs in the Architecture and Concepts docs.
Inputs
The Managementtunnel resource accepts the following input properties:
- Allow
Collect stringStatistics - Enable/disable collection of run time statistics. Valid values:
enable
,disable
. - Allow
Config stringRestore - Enable/disable allow config restore. Valid values:
enable
,disable
. - Allow
Push stringConfiguration - Enable/disable push configuration. Valid values:
enable
,disable
. - Allow
Push stringFirmware - Enable/disable push firmware. Valid values:
enable
,disable
. - string
- Enable/disable restriction of authorized manager only. Valid values:
enable
,disable
. - Serial
Number string - Serial number.
- Status string
- Enable/disable FGFM tunnel. Valid values:
enable
,disable
. - Vdomparam string
- Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
- Allow
Collect stringStatistics - Enable/disable collection of run time statistics. Valid values:
enable
,disable
. - Allow
Config stringRestore - Enable/disable allow config restore. Valid values:
enable
,disable
. - Allow
Push stringConfiguration - Enable/disable push configuration. Valid values:
enable
,disable
. - Allow
Push stringFirmware - Enable/disable push firmware. Valid values:
enable
,disable
. - string
- Enable/disable restriction of authorized manager only. Valid values:
enable
,disable
. - Serial
Number string - Serial number.
- Status string
- Enable/disable FGFM tunnel. Valid values:
enable
,disable
. - Vdomparam string
- Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
- allow
Collect StringStatistics - Enable/disable collection of run time statistics. Valid values:
enable
,disable
. - allow
Config StringRestore - Enable/disable allow config restore. Valid values:
enable
,disable
. - allow
Push StringConfiguration - Enable/disable push configuration. Valid values:
enable
,disable
. - allow
Push StringFirmware - Enable/disable push firmware. Valid values:
enable
,disable
. - String
- Enable/disable restriction of authorized manager only. Valid values:
enable
,disable
. - serial
Number String - Serial number.
- status String
- Enable/disable FGFM tunnel. Valid values:
enable
,disable
. - vdomparam String
- Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
- allow
Collect stringStatistics - Enable/disable collection of run time statistics. Valid values:
enable
,disable
. - allow
Config stringRestore - Enable/disable allow config restore. Valid values:
enable
,disable
. - allow
Push stringConfiguration - Enable/disable push configuration. Valid values:
enable
,disable
. - allow
Push stringFirmware - Enable/disable push firmware. Valid values:
enable
,disable
. - string
- Enable/disable restriction of authorized manager only. Valid values:
enable
,disable
. - serial
Number string - Serial number.
- status string
- Enable/disable FGFM tunnel. Valid values:
enable
,disable
. - vdomparam string
- Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
- allow_
collect_ strstatistics - Enable/disable collection of run time statistics. Valid values:
enable
,disable
. - allow_
config_ strrestore - Enable/disable allow config restore. Valid values:
enable
,disable
. - allow_
push_ strconfiguration - Enable/disable push configuration. Valid values:
enable
,disable
. - allow_
push_ strfirmware - Enable/disable push firmware. Valid values:
enable
,disable
. - str
- Enable/disable restriction of authorized manager only. Valid values:
enable
,disable
. - serial_
number str - Serial number.
- status str
- Enable/disable FGFM tunnel. Valid values:
enable
,disable
. - vdomparam str
- Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
- allow
Collect StringStatistics - Enable/disable collection of run time statistics. Valid values:
enable
,disable
. - allow
Config StringRestore - Enable/disable allow config restore. Valid values:
enable
,disable
. - allow
Push StringConfiguration - Enable/disable push configuration. Valid values:
enable
,disable
. - allow
Push StringFirmware - Enable/disable push firmware. Valid values:
enable
,disable
. - String
- Enable/disable restriction of authorized manager only. Valid values:
enable
,disable
. - serial
Number String - Serial number.
- status String
- Enable/disable FGFM tunnel. Valid values:
enable
,disable
. - vdomparam String
- Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
Outputs
All input properties are implicitly available as output properties. Additionally, the Managementtunnel resource produces the following output properties:
- Id string
- The provider-assigned unique ID for this managed resource.
- Id string
- The provider-assigned unique ID for this managed resource.
- id String
- The provider-assigned unique ID for this managed resource.
- id string
- The provider-assigned unique ID for this managed resource.
- id str
- The provider-assigned unique ID for this managed resource.
- id String
- The provider-assigned unique ID for this managed resource.
Look up Existing Managementtunnel Resource
Get an existing Managementtunnel resource’s state with the given name, ID, and optional extra properties used to qualify the lookup.
public static get(name: string, id: Input<ID>, state?: ManagementtunnelState, opts?: CustomResourceOptions): Managementtunnel
@staticmethod
def get(resource_name: str,
id: str,
opts: Optional[ResourceOptions] = None,
allow_collect_statistics: Optional[str] = None,
allow_config_restore: Optional[str] = None,
allow_push_configuration: Optional[str] = None,
allow_push_firmware: Optional[str] = None,
authorized_manager_only: Optional[str] = None,
serial_number: Optional[str] = None,
status: Optional[str] = None,
vdomparam: Optional[str] = None) -> Managementtunnel
func GetManagementtunnel(ctx *Context, name string, id IDInput, state *ManagementtunnelState, opts ...ResourceOption) (*Managementtunnel, error)
public static Managementtunnel Get(string name, Input<string> id, ManagementtunnelState? state, CustomResourceOptions? opts = null)
public static Managementtunnel get(String name, Output<String> id, ManagementtunnelState state, CustomResourceOptions options)
Resource lookup is not supported in YAML
- name
- The unique name of the resulting resource.
- id
- The unique provider ID of the resource to lookup.
- state
- Any extra arguments used during the lookup.
- opts
- A bag of options that control this resource's behavior.
- resource_name
- The unique name of the resulting resource.
- id
- The unique provider ID of the resource to lookup.
- name
- The unique name of the resulting resource.
- id
- The unique provider ID of the resource to lookup.
- state
- Any extra arguments used during the lookup.
- opts
- A bag of options that control this resource's behavior.
- name
- The unique name of the resulting resource.
- id
- The unique provider ID of the resource to lookup.
- state
- Any extra arguments used during the lookup.
- opts
- A bag of options that control this resource's behavior.
- name
- The unique name of the resulting resource.
- id
- The unique provider ID of the resource to lookup.
- state
- Any extra arguments used during the lookup.
- opts
- A bag of options that control this resource's behavior.
- Allow
Collect stringStatistics - Enable/disable collection of run time statistics. Valid values:
enable
,disable
. - Allow
Config stringRestore - Enable/disable allow config restore. Valid values:
enable
,disable
. - Allow
Push stringConfiguration - Enable/disable push configuration. Valid values:
enable
,disable
. - Allow
Push stringFirmware - Enable/disable push firmware. Valid values:
enable
,disable
. - string
- Enable/disable restriction of authorized manager only. Valid values:
enable
,disable
. - Serial
Number string - Serial number.
- Status string
- Enable/disable FGFM tunnel. Valid values:
enable
,disable
. - Vdomparam string
- Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
- Allow
Collect stringStatistics - Enable/disable collection of run time statistics. Valid values:
enable
,disable
. - Allow
Config stringRestore - Enable/disable allow config restore. Valid values:
enable
,disable
. - Allow
Push stringConfiguration - Enable/disable push configuration. Valid values:
enable
,disable
. - Allow
Push stringFirmware - Enable/disable push firmware. Valid values:
enable
,disable
. - string
- Enable/disable restriction of authorized manager only. Valid values:
enable
,disable
. - Serial
Number string - Serial number.
- Status string
- Enable/disable FGFM tunnel. Valid values:
enable
,disable
. - Vdomparam string
- Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
- allow
Collect StringStatistics - Enable/disable collection of run time statistics. Valid values:
enable
,disable
. - allow
Config StringRestore - Enable/disable allow config restore. Valid values:
enable
,disable
. - allow
Push StringConfiguration - Enable/disable push configuration. Valid values:
enable
,disable
. - allow
Push StringFirmware - Enable/disable push firmware. Valid values:
enable
,disable
. - String
- Enable/disable restriction of authorized manager only. Valid values:
enable
,disable
. - serial
Number String - Serial number.
- status String
- Enable/disable FGFM tunnel. Valid values:
enable
,disable
. - vdomparam String
- Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
- allow
Collect stringStatistics - Enable/disable collection of run time statistics. Valid values:
enable
,disable
. - allow
Config stringRestore - Enable/disable allow config restore. Valid values:
enable
,disable
. - allow
Push stringConfiguration - Enable/disable push configuration. Valid values:
enable
,disable
. - allow
Push stringFirmware - Enable/disable push firmware. Valid values:
enable
,disable
. - string
- Enable/disable restriction of authorized manager only. Valid values:
enable
,disable
. - serial
Number string - Serial number.
- status string
- Enable/disable FGFM tunnel. Valid values:
enable
,disable
. - vdomparam string
- Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
- allow_
collect_ strstatistics - Enable/disable collection of run time statistics. Valid values:
enable
,disable
. - allow_
config_ strrestore - Enable/disable allow config restore. Valid values:
enable
,disable
. - allow_
push_ strconfiguration - Enable/disable push configuration. Valid values:
enable
,disable
. - allow_
push_ strfirmware - Enable/disable push firmware. Valid values:
enable
,disable
. - str
- Enable/disable restriction of authorized manager only. Valid values:
enable
,disable
. - serial_
number str - Serial number.
- status str
- Enable/disable FGFM tunnel. Valid values:
enable
,disable
. - vdomparam str
- Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
- allow
Collect StringStatistics - Enable/disable collection of run time statistics. Valid values:
enable
,disable
. - allow
Config StringRestore - Enable/disable allow config restore. Valid values:
enable
,disable
. - allow
Push StringConfiguration - Enable/disable push configuration. Valid values:
enable
,disable
. - allow
Push StringFirmware - Enable/disable push firmware. Valid values:
enable
,disable
. - String
- Enable/disable restriction of authorized manager only. Valid values:
enable
,disable
. - serial
Number String - Serial number.
- status String
- Enable/disable FGFM tunnel. Valid values:
enable
,disable
. - vdomparam String
- Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
Import
System ManagementTunnel can be imported using any of these accepted formats:
$ pulumi import fortios:system/managementtunnel:Managementtunnel labelname SystemManagementTunnel
If you do not want to import arguments of block:
$ export “FORTIOS_IMPORT_TABLE”=“false”
$ pulumi import fortios:system/managementtunnel:Managementtunnel labelname SystemManagementTunnel
$ unset “FORTIOS_IMPORT_TABLE”
To learn more about importing existing cloud resources, see Importing resources.
Package Details
- Repository
- fortios pulumiverse/pulumi-fortios
- License
- Apache-2.0
- Notes
- This Pulumi package is based on the
fortios
Terraform Provider.