Cisco Meraki v0.3.2 published on Tuesday, Sep 24, 2024 by Pulumi
meraki.organizations.getWirelessDevicesChannelUtilizationByDevice
Explore with Pulumi AI
Example Usage
import * as pulumi from "@pulumi/pulumi";
import * as meraki from "@pulumi/meraki";
const example = meraki.organizations.getWirelessDevicesChannelUtilizationByDevice({
endingBefore: "string",
interval: 1,
networkIds: ["string"],
organizationId: "string",
perPage: 1,
serials: ["string"],
startingAfter: "string",
t0: "string",
t1: "string",
timespan: 1,
});
export const merakiOrganizationsWirelessDevicesChannelUtilizationByDeviceExample = example.then(example => example.items);
import pulumi
import pulumi_meraki as meraki
example = meraki.organizations.get_wireless_devices_channel_utilization_by_device(ending_before="string",
interval=1,
network_ids=["string"],
organization_id="string",
per_page=1,
serials=["string"],
starting_after="string",
t0="string",
t1="string",
timespan=1)
pulumi.export("merakiOrganizationsWirelessDevicesChannelUtilizationByDeviceExample", example.items)
package main
import (
"github.com/pulumi/pulumi-meraki/sdk/go/meraki/organizations"
"github.com/pulumi/pulumi/sdk/v3/go/pulumi"
)
func main() {
pulumi.Run(func(ctx *pulumi.Context) error {
example, err := organizations.GetWirelessDevicesChannelUtilizationByDevice(ctx, &organizations.GetWirelessDevicesChannelUtilizationByDeviceArgs{
EndingBefore: pulumi.StringRef("string"),
Interval: pulumi.IntRef(1),
NetworkIds: []string{
"string",
},
OrganizationId: "string",
PerPage: pulumi.IntRef(1),
Serials: []string{
"string",
},
StartingAfter: pulumi.StringRef("string"),
T0: pulumi.StringRef("string"),
T1: pulumi.StringRef("string"),
Timespan: pulumi.Float64Ref(1),
}, nil)
if err != nil {
return err
}
ctx.Export("merakiOrganizationsWirelessDevicesChannelUtilizationByDeviceExample", example.Items)
return nil
})
}
using System.Collections.Generic;
using System.Linq;
using Pulumi;
using Meraki = Pulumi.Meraki;
return await Deployment.RunAsync(() =>
{
var example = Meraki.Organizations.GetWirelessDevicesChannelUtilizationByDevice.Invoke(new()
{
EndingBefore = "string",
Interval = 1,
NetworkIds = new[]
{
"string",
},
OrganizationId = "string",
PerPage = 1,
Serials = new[]
{
"string",
},
StartingAfter = "string",
T0 = "string",
T1 = "string",
Timespan = 1,
});
return new Dictionary<string, object?>
{
["merakiOrganizationsWirelessDevicesChannelUtilizationByDeviceExample"] = example.Apply(getWirelessDevicesChannelUtilizationByDeviceResult => getWirelessDevicesChannelUtilizationByDeviceResult.Items),
};
});
package generated_program;
import com.pulumi.Context;
import com.pulumi.Pulumi;
import com.pulumi.core.Output;
import com.pulumi.meraki.organizations.OrganizationsFunctions;
import com.pulumi.meraki.organizations.inputs.GetWirelessDevicesChannelUtilizationByDeviceArgs;
import java.util.List;
import java.util.ArrayList;
import java.util.Map;
import java.io.File;
import java.nio.file.Files;
import java.nio.file.Paths;
public class App {
public static void main(String[] args) {
Pulumi.run(App::stack);
}
public static void stack(Context ctx) {
final var example = OrganizationsFunctions.getWirelessDevicesChannelUtilizationByDevice(GetWirelessDevicesChannelUtilizationByDeviceArgs.builder()
.endingBefore("string")
.interval(1)
.networkIds("string")
.organizationId("string")
.perPage(1)
.serials("string")
.startingAfter("string")
.t0("string")
.t1("string")
.timespan(1)
.build());
ctx.export("merakiOrganizationsWirelessDevicesChannelUtilizationByDeviceExample", example.applyValue(getWirelessDevicesChannelUtilizationByDeviceResult -> getWirelessDevicesChannelUtilizationByDeviceResult.items()));
}
}
variables:
example:
fn::invoke:
Function: meraki:organizations:getWirelessDevicesChannelUtilizationByDevice
Arguments:
endingBefore: string
interval: 1
networkIds:
- string
organizationId: string
perPage: 1
serials:
- string
startingAfter: string
t0: string
t1: string
timespan: 1
outputs:
merakiOrganizationsWirelessDevicesChannelUtilizationByDeviceExample: ${example.items}
Using getWirelessDevicesChannelUtilizationByDevice
Two invocation forms are available. The direct form accepts plain arguments and either blocks until the result value is available, or returns a Promise-wrapped result. The output form accepts Input-wrapped arguments and returns an Output-wrapped result.
function getWirelessDevicesChannelUtilizationByDevice(args: GetWirelessDevicesChannelUtilizationByDeviceArgs, opts?: InvokeOptions): Promise<GetWirelessDevicesChannelUtilizationByDeviceResult>
function getWirelessDevicesChannelUtilizationByDeviceOutput(args: GetWirelessDevicesChannelUtilizationByDeviceOutputArgs, opts?: InvokeOptions): Output<GetWirelessDevicesChannelUtilizationByDeviceResult>
def get_wireless_devices_channel_utilization_by_device(ending_before: Optional[str] = None,
interval: Optional[int] = None,
network_ids: Optional[Sequence[str]] = None,
organization_id: Optional[str] = None,
per_page: Optional[int] = None,
serials: Optional[Sequence[str]] = None,
starting_after: Optional[str] = None,
t0: Optional[str] = None,
t1: Optional[str] = None,
timespan: Optional[float] = None,
opts: Optional[InvokeOptions] = None) -> GetWirelessDevicesChannelUtilizationByDeviceResult
def get_wireless_devices_channel_utilization_by_device_output(ending_before: Optional[pulumi.Input[str]] = None,
interval: Optional[pulumi.Input[int]] = None,
network_ids: Optional[pulumi.Input[Sequence[pulumi.Input[str]]]] = None,
organization_id: Optional[pulumi.Input[str]] = None,
per_page: Optional[pulumi.Input[int]] = None,
serials: Optional[pulumi.Input[Sequence[pulumi.Input[str]]]] = None,
starting_after: Optional[pulumi.Input[str]] = None,
t0: Optional[pulumi.Input[str]] = None,
t1: Optional[pulumi.Input[str]] = None,
timespan: Optional[pulumi.Input[float]] = None,
opts: Optional[InvokeOptions] = None) -> Output[GetWirelessDevicesChannelUtilizationByDeviceResult]
func GetWirelessDevicesChannelUtilizationByDevice(ctx *Context, args *GetWirelessDevicesChannelUtilizationByDeviceArgs, opts ...InvokeOption) (*GetWirelessDevicesChannelUtilizationByDeviceResult, error)
func GetWirelessDevicesChannelUtilizationByDeviceOutput(ctx *Context, args *GetWirelessDevicesChannelUtilizationByDeviceOutputArgs, opts ...InvokeOption) GetWirelessDevicesChannelUtilizationByDeviceResultOutput
> Note: This function is named GetWirelessDevicesChannelUtilizationByDevice
in the Go SDK.
public static class GetWirelessDevicesChannelUtilizationByDevice
{
public static Task<GetWirelessDevicesChannelUtilizationByDeviceResult> InvokeAsync(GetWirelessDevicesChannelUtilizationByDeviceArgs args, InvokeOptions? opts = null)
public static Output<GetWirelessDevicesChannelUtilizationByDeviceResult> Invoke(GetWirelessDevicesChannelUtilizationByDeviceInvokeArgs args, InvokeOptions? opts = null)
}
public static CompletableFuture<GetWirelessDevicesChannelUtilizationByDeviceResult> getWirelessDevicesChannelUtilizationByDevice(GetWirelessDevicesChannelUtilizationByDeviceArgs args, InvokeOptions options)
// Output-based functions aren't available in Java yet
fn::invoke:
function: meraki:organizations/getWirelessDevicesChannelUtilizationByDevice:getWirelessDevicesChannelUtilizationByDevice
arguments:
# arguments dictionary
The following arguments are supported:
- Organization
Id string - organizationId path parameter. Organization ID
- Ending
Before string - endingBefore query parameter. A token used by the server to indicate the end of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- Interval int
- interval query parameter. The time interval in seconds for returned data. The valid intervals are: 300, 600, 3600, 7200, 14400, 21600. The default is 3600.
- Network
Ids List<string> - networkIds query parameter. Filter results by network.
- Per
Page int - perPage query parameter. The number of entries per page returned. Acceptable range is 3 1000. Default is 1000.
- Serials List<string>
- serials query parameter. Filter results by device.
- Starting
After string - startingAfter query parameter. A token used by the server to indicate the start of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- T0 string
- t0 query parameter. The beginning of the timespan for the data. The maximum lookback period is 90 days from today.
- T1 string
- t1 query parameter. The end of the timespan for the data. t1 can be a maximum of 90 days after t0.
- Timespan double
- timespan query parameter. The timespan for which the information will be fetched. If specifying timespan, do not specify parameters t0 and t1. The value must be in seconds and be less than or equal to 90 days. The default is 7 days.
- Organization
Id string - organizationId path parameter. Organization ID
- Ending
Before string - endingBefore query parameter. A token used by the server to indicate the end of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- Interval int
- interval query parameter. The time interval in seconds for returned data. The valid intervals are: 300, 600, 3600, 7200, 14400, 21600. The default is 3600.
- Network
Ids []string - networkIds query parameter. Filter results by network.
- Per
Page int - perPage query parameter. The number of entries per page returned. Acceptable range is 3 1000. Default is 1000.
- Serials []string
- serials query parameter. Filter results by device.
- Starting
After string - startingAfter query parameter. A token used by the server to indicate the start of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- T0 string
- t0 query parameter. The beginning of the timespan for the data. The maximum lookback period is 90 days from today.
- T1 string
- t1 query parameter. The end of the timespan for the data. t1 can be a maximum of 90 days after t0.
- Timespan float64
- timespan query parameter. The timespan for which the information will be fetched. If specifying timespan, do not specify parameters t0 and t1. The value must be in seconds and be less than or equal to 90 days. The default is 7 days.
- organization
Id String - organizationId path parameter. Organization ID
- ending
Before String - endingBefore query parameter. A token used by the server to indicate the end of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- interval Integer
- interval query parameter. The time interval in seconds for returned data. The valid intervals are: 300, 600, 3600, 7200, 14400, 21600. The default is 3600.
- network
Ids List<String> - networkIds query parameter. Filter results by network.
- per
Page Integer - perPage query parameter. The number of entries per page returned. Acceptable range is 3 1000. Default is 1000.
- serials List<String>
- serials query parameter. Filter results by device.
- starting
After String - startingAfter query parameter. A token used by the server to indicate the start of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- t0 String
- t0 query parameter. The beginning of the timespan for the data. The maximum lookback period is 90 days from today.
- t1 String
- t1 query parameter. The end of the timespan for the data. t1 can be a maximum of 90 days after t0.
- timespan Double
- timespan query parameter. The timespan for which the information will be fetched. If specifying timespan, do not specify parameters t0 and t1. The value must be in seconds and be less than or equal to 90 days. The default is 7 days.
- organization
Id string - organizationId path parameter. Organization ID
- ending
Before string - endingBefore query parameter. A token used by the server to indicate the end of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- interval number
- interval query parameter. The time interval in seconds for returned data. The valid intervals are: 300, 600, 3600, 7200, 14400, 21600. The default is 3600.
- network
Ids string[] - networkIds query parameter. Filter results by network.
- per
Page number - perPage query parameter. The number of entries per page returned. Acceptable range is 3 1000. Default is 1000.
- serials string[]
- serials query parameter. Filter results by device.
- starting
After string - startingAfter query parameter. A token used by the server to indicate the start of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- t0 string
- t0 query parameter. The beginning of the timespan for the data. The maximum lookback period is 90 days from today.
- t1 string
- t1 query parameter. The end of the timespan for the data. t1 can be a maximum of 90 days after t0.
- timespan number
- timespan query parameter. The timespan for which the information will be fetched. If specifying timespan, do not specify parameters t0 and t1. The value must be in seconds and be less than or equal to 90 days. The default is 7 days.
- organization_
id str - organizationId path parameter. Organization ID
- ending_
before str - endingBefore query parameter. A token used by the server to indicate the end of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- interval int
- interval query parameter. The time interval in seconds for returned data. The valid intervals are: 300, 600, 3600, 7200, 14400, 21600. The default is 3600.
- network_
ids Sequence[str] - networkIds query parameter. Filter results by network.
- per_
page int - perPage query parameter. The number of entries per page returned. Acceptable range is 3 1000. Default is 1000.
- serials Sequence[str]
- serials query parameter. Filter results by device.
- starting_
after str - startingAfter query parameter. A token used by the server to indicate the start of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- t0 str
- t0 query parameter. The beginning of the timespan for the data. The maximum lookback period is 90 days from today.
- t1 str
- t1 query parameter. The end of the timespan for the data. t1 can be a maximum of 90 days after t0.
- timespan float
- timespan query parameter. The timespan for which the information will be fetched. If specifying timespan, do not specify parameters t0 and t1. The value must be in seconds and be less than or equal to 90 days. The default is 7 days.
- organization
Id String - organizationId path parameter. Organization ID
- ending
Before String - endingBefore query parameter. A token used by the server to indicate the end of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- interval Number
- interval query parameter. The time interval in seconds for returned data. The valid intervals are: 300, 600, 3600, 7200, 14400, 21600. The default is 3600.
- network
Ids List<String> - networkIds query parameter. Filter results by network.
- per
Page Number - perPage query parameter. The number of entries per page returned. Acceptable range is 3 1000. Default is 1000.
- serials List<String>
- serials query parameter. Filter results by device.
- starting
After String - startingAfter query parameter. A token used by the server to indicate the start of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- t0 String
- t0 query parameter. The beginning of the timespan for the data. The maximum lookback period is 90 days from today.
- t1 String
- t1 query parameter. The end of the timespan for the data. t1 can be a maximum of 90 days after t0.
- timespan Number
- timespan query parameter. The timespan for which the information will be fetched. If specifying timespan, do not specify parameters t0 and t1. The value must be in seconds and be less than or equal to 90 days. The default is 7 days.
getWirelessDevicesChannelUtilizationByDevice Result
The following output properties are available:
- Id string
- The provider-assigned unique ID for this managed resource.
- Items
List<Get
Wireless Devices Channel Utilization By Device Item> - Array of ResponseWirelessGetOrganizationWirelessDevicesChannelUtilizationByDevice
- Organization
Id string - organizationId path parameter. Organization ID
- Ending
Before string - endingBefore query parameter. A token used by the server to indicate the end of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- Interval int
- interval query parameter. The time interval in seconds for returned data. The valid intervals are: 300, 600, 3600, 7200, 14400, 21600. The default is 3600.
- Network
Ids List<string> - networkIds query parameter. Filter results by network.
- Per
Page int - perPage query parameter. The number of entries per page returned. Acceptable range is 3 1000. Default is 1000.
- Serials List<string>
- serials query parameter. Filter results by device.
- Starting
After string - startingAfter query parameter. A token used by the server to indicate the start of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- T0 string
- t0 query parameter. The beginning of the timespan for the data. The maximum lookback period is 90 days from today.
- T1 string
- t1 query parameter. The end of the timespan for the data. t1 can be a maximum of 90 days after t0.
- Timespan double
- timespan query parameter. The timespan for which the information will be fetched. If specifying timespan, do not specify parameters t0 and t1. The value must be in seconds and be less than or equal to 90 days. The default is 7 days.
- Id string
- The provider-assigned unique ID for this managed resource.
- Items
[]Get
Wireless Devices Channel Utilization By Device Item - Array of ResponseWirelessGetOrganizationWirelessDevicesChannelUtilizationByDevice
- Organization
Id string - organizationId path parameter. Organization ID
- Ending
Before string - endingBefore query parameter. A token used by the server to indicate the end of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- Interval int
- interval query parameter. The time interval in seconds for returned data. The valid intervals are: 300, 600, 3600, 7200, 14400, 21600. The default is 3600.
- Network
Ids []string - networkIds query parameter. Filter results by network.
- Per
Page int - perPage query parameter. The number of entries per page returned. Acceptable range is 3 1000. Default is 1000.
- Serials []string
- serials query parameter. Filter results by device.
- Starting
After string - startingAfter query parameter. A token used by the server to indicate the start of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- T0 string
- t0 query parameter. The beginning of the timespan for the data. The maximum lookback period is 90 days from today.
- T1 string
- t1 query parameter. The end of the timespan for the data. t1 can be a maximum of 90 days after t0.
- Timespan float64
- timespan query parameter. The timespan for which the information will be fetched. If specifying timespan, do not specify parameters t0 and t1. The value must be in seconds and be less than or equal to 90 days. The default is 7 days.
- id String
- The provider-assigned unique ID for this managed resource.
- items
List<Get
Wireless Devices Channel Utilization By Device Item> - Array of ResponseWirelessGetOrganizationWirelessDevicesChannelUtilizationByDevice
- organization
Id String - organizationId path parameter. Organization ID
- ending
Before String - endingBefore query parameter. A token used by the server to indicate the end of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- interval Integer
- interval query parameter. The time interval in seconds for returned data. The valid intervals are: 300, 600, 3600, 7200, 14400, 21600. The default is 3600.
- network
Ids List<String> - networkIds query parameter. Filter results by network.
- per
Page Integer - perPage query parameter. The number of entries per page returned. Acceptable range is 3 1000. Default is 1000.
- serials List<String>
- serials query parameter. Filter results by device.
- starting
After String - startingAfter query parameter. A token used by the server to indicate the start of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- t0 String
- t0 query parameter. The beginning of the timespan for the data. The maximum lookback period is 90 days from today.
- t1 String
- t1 query parameter. The end of the timespan for the data. t1 can be a maximum of 90 days after t0.
- timespan Double
- timespan query parameter. The timespan for which the information will be fetched. If specifying timespan, do not specify parameters t0 and t1. The value must be in seconds and be less than or equal to 90 days. The default is 7 days.
- id string
- The provider-assigned unique ID for this managed resource.
- items
Get
Wireless Devices Channel Utilization By Device Item[] - Array of ResponseWirelessGetOrganizationWirelessDevicesChannelUtilizationByDevice
- organization
Id string - organizationId path parameter. Organization ID
- ending
Before string - endingBefore query parameter. A token used by the server to indicate the end of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- interval number
- interval query parameter. The time interval in seconds for returned data. The valid intervals are: 300, 600, 3600, 7200, 14400, 21600. The default is 3600.
- network
Ids string[] - networkIds query parameter. Filter results by network.
- per
Page number - perPage query parameter. The number of entries per page returned. Acceptable range is 3 1000. Default is 1000.
- serials string[]
- serials query parameter. Filter results by device.
- starting
After string - startingAfter query parameter. A token used by the server to indicate the start of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- t0 string
- t0 query parameter. The beginning of the timespan for the data. The maximum lookback period is 90 days from today.
- t1 string
- t1 query parameter. The end of the timespan for the data. t1 can be a maximum of 90 days after t0.
- timespan number
- timespan query parameter. The timespan for which the information will be fetched. If specifying timespan, do not specify parameters t0 and t1. The value must be in seconds and be less than or equal to 90 days. The default is 7 days.
- id str
- The provider-assigned unique ID for this managed resource.
- items
Sequence[Get
Wireless Devices Channel Utilization By Device Item] - Array of ResponseWirelessGetOrganizationWirelessDevicesChannelUtilizationByDevice
- organization_
id str - organizationId path parameter. Organization ID
- ending_
before str - endingBefore query parameter. A token used by the server to indicate the end of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- interval int
- interval query parameter. The time interval in seconds for returned data. The valid intervals are: 300, 600, 3600, 7200, 14400, 21600. The default is 3600.
- network_
ids Sequence[str] - networkIds query parameter. Filter results by network.
- per_
page int - perPage query parameter. The number of entries per page returned. Acceptable range is 3 1000. Default is 1000.
- serials Sequence[str]
- serials query parameter. Filter results by device.
- starting_
after str - startingAfter query parameter. A token used by the server to indicate the start of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- t0 str
- t0 query parameter. The beginning of the timespan for the data. The maximum lookback period is 90 days from today.
- t1 str
- t1 query parameter. The end of the timespan for the data. t1 can be a maximum of 90 days after t0.
- timespan float
- timespan query parameter. The timespan for which the information will be fetched. If specifying timespan, do not specify parameters t0 and t1. The value must be in seconds and be less than or equal to 90 days. The default is 7 days.
- id String
- The provider-assigned unique ID for this managed resource.
- items List<Property Map>
- Array of ResponseWirelessGetOrganizationWirelessDevicesChannelUtilizationByDevice
- organization
Id String - organizationId path parameter. Organization ID
- ending
Before String - endingBefore query parameter. A token used by the server to indicate the end of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- interval Number
- interval query parameter. The time interval in seconds for returned data. The valid intervals are: 300, 600, 3600, 7200, 14400, 21600. The default is 3600.
- network
Ids List<String> - networkIds query parameter. Filter results by network.
- per
Page Number - perPage query parameter. The number of entries per page returned. Acceptable range is 3 1000. Default is 1000.
- serials List<String>
- serials query parameter. Filter results by device.
- starting
After String - startingAfter query parameter. A token used by the server to indicate the start of the page. Often this is a timestamp or an ID but it is not limited to those. This parameter should not be defined by client applications. The link for the first, last, prev, or next page in the HTTP Link header should define it.
- t0 String
- t0 query parameter. The beginning of the timespan for the data. The maximum lookback period is 90 days from today.
- t1 String
- t1 query parameter. The end of the timespan for the data. t1 can be a maximum of 90 days after t0.
- timespan Number
- timespan query parameter. The timespan for which the information will be fetched. If specifying timespan, do not specify parameters t0 and t1. The value must be in seconds and be less than or equal to 90 days. The default is 7 days.
Supporting Types
GetWirelessDevicesChannelUtilizationByDeviceItem
- By
Bands List<GetWireless Devices Channel Utilization By Device Item By Band> - Channel utilization broken down by band.
- Mac string
- The MAC address of the device.
- Network
Get
Wireless Devices Channel Utilization By Device Item Network - Network for the given utilization metrics.
- Serial string
- The serial number for the device.
- By
Bands []GetWireless Devices Channel Utilization By Device Item By Band - Channel utilization broken down by band.
- Mac string
- The MAC address of the device.
- Network
Get
Wireless Devices Channel Utilization By Device Item Network - Network for the given utilization metrics.
- Serial string
- The serial number for the device.
- by
Bands List<GetWireless Devices Channel Utilization By Device Item By Band> - Channel utilization broken down by band.
- mac String
- The MAC address of the device.
- network
Get
Wireless Devices Channel Utilization By Device Item Network - Network for the given utilization metrics.
- serial String
- The serial number for the device.
- by
Bands GetWireless Devices Channel Utilization By Device Item By Band[] - Channel utilization broken down by band.
- mac string
- The MAC address of the device.
- network
Get
Wireless Devices Channel Utilization By Device Item Network - Network for the given utilization metrics.
- serial string
- The serial number for the device.
- by_
bands Sequence[GetWireless Devices Channel Utilization By Device Item By Band] - Channel utilization broken down by band.
- mac str
- The MAC address of the device.
- network
Get
Wireless Devices Channel Utilization By Device Item Network - Network for the given utilization metrics.
- serial str
- The serial number for the device.
- by
Bands List<Property Map> - Channel utilization broken down by band.
- mac String
- The MAC address of the device.
- network Property Map
- Network for the given utilization metrics.
- serial String
- The serial number for the device.
GetWirelessDevicesChannelUtilizationByDeviceItemByBand
- Band string
- The band for the given metrics.
- Non
Wifi GetWireless Devices Channel Utilization By Device Item By Band Non Wifi - An object containing non-wifi utilization.
- Total
Get
Wireless Devices Channel Utilization By Device Item By Band Total - An object containing total channel utilization.
- Wifi
Get
Wireless Devices Channel Utilization By Device Item By Band Wifi - An object containing wifi utilization.
- Band string
- The band for the given metrics.
- Non
Wifi GetWireless Devices Channel Utilization By Device Item By Band Non Wifi - An object containing non-wifi utilization.
- Total
Get
Wireless Devices Channel Utilization By Device Item By Band Total - An object containing total channel utilization.
- Wifi
Get
Wireless Devices Channel Utilization By Device Item By Band Wifi - An object containing wifi utilization.
- band String
- The band for the given metrics.
- non
Wifi GetWireless Devices Channel Utilization By Device Item By Band Non Wifi - An object containing non-wifi utilization.
- total
Get
Wireless Devices Channel Utilization By Device Item By Band Total - An object containing total channel utilization.
- wifi
Get
Wireless Devices Channel Utilization By Device Item By Band Wifi - An object containing wifi utilization.
- band string
- The band for the given metrics.
- non
Wifi GetWireless Devices Channel Utilization By Device Item By Band Non Wifi - An object containing non-wifi utilization.
- total
Get
Wireless Devices Channel Utilization By Device Item By Band Total - An object containing total channel utilization.
- wifi
Get
Wireless Devices Channel Utilization By Device Item By Band Wifi - An object containing wifi utilization.
- band str
- The band for the given metrics.
- non_
wifi GetWireless Devices Channel Utilization By Device Item By Band Non Wifi - An object containing non-wifi utilization.
- total
Get
Wireless Devices Channel Utilization By Device Item By Band Total - An object containing total channel utilization.
- wifi
Get
Wireless Devices Channel Utilization By Device Item By Band Wifi - An object containing wifi utilization.
- band String
- The band for the given metrics.
- non
Wifi Property Map - An object containing non-wifi utilization.
- total Property Map
- An object containing total channel utilization.
- wifi Property Map
- An object containing wifi utilization.
GetWirelessDevicesChannelUtilizationByDeviceItemByBandNonWifi
- Percentage double
- Percentage of non-wifi channel utiliation for the given band.
- Percentage float64
- Percentage of non-wifi channel utiliation for the given band.
- percentage Double
- Percentage of non-wifi channel utiliation for the given band.
- percentage number
- Percentage of non-wifi channel utiliation for the given band.
- percentage float
- Percentage of non-wifi channel utiliation for the given band.
- percentage Number
- Percentage of non-wifi channel utiliation for the given band.
GetWirelessDevicesChannelUtilizationByDeviceItemByBandTotal
- Percentage double
- Percentage of total channel utiliation for the given band.
- Percentage float64
- Percentage of total channel utiliation for the given band.
- percentage Double
- Percentage of total channel utiliation for the given band.
- percentage number
- Percentage of total channel utiliation for the given band.
- percentage float
- Percentage of total channel utiliation for the given band.
- percentage Number
- Percentage of total channel utiliation for the given band.
GetWirelessDevicesChannelUtilizationByDeviceItemByBandWifi
- Percentage double
- Percentage of wifi channel utiliation for the given band.
- Percentage float64
- Percentage of wifi channel utiliation for the given band.
- percentage Double
- Percentage of wifi channel utiliation for the given band.
- percentage number
- Percentage of wifi channel utiliation for the given band.
- percentage float
- Percentage of wifi channel utiliation for the given band.
- percentage Number
- Percentage of wifi channel utiliation for the given band.
GetWirelessDevicesChannelUtilizationByDeviceItemNetwork
- Id string
- Network ID of the given utilization metrics.
- Id string
- Network ID of the given utilization metrics.
- id String
- Network ID of the given utilization metrics.
- id string
- Network ID of the given utilization metrics.
- id str
- Network ID of the given utilization metrics.
- id String
- Network ID of the given utilization metrics.
Package Details
- Repository
- meraki pulumi/pulumi-meraki
- License
- Apache-2.0
- Notes
- This Pulumi package is based on the
meraki
Terraform Provider.